Coolant Mist Collector Manufacturers, Suppliers in India | AIR PEL TECHNIC

Coolant Mist Collector Manufacturers | AIR PEL TECHNIC
whatsapp-now
enquire-now

AIR PEL TECHNIC is the recommended coolant mist collector manufacturers in India, suppliers, service providers in India, which offer reliable and efficient solutions of industrial air quality. Our mission statement falls under an improvement in operational efficiency and safety through a diversified product offering of those systems to remove other airborne contaminants. Our aim is to provide superior products that are made in India that will fulfil the particular niche requirements of our clients and that will enhance working conditions.

Product – Coolant Mist Collectors

AIR PEL TECHNIC offers Coolant Mist Collectors for various machining Process, Enhances safety by reducing slippery floors & fire hazards and Ensures compliance with industrial safety standards. With our source capture and air filtration systems you can achieve this by eliminating safety hazards in the turning of a manufacturing plant into a high-performance facility where safety and productivity are synonymous.

Types of Coolant Mist Collector

  • Centrifugal Mist Collectors: These types of collectors incorporate an extremely high-powered revolving drum or impeller, creating centrifugal force which throws the particulate of mist against the inner walls of the collector.
Technical Data Details
Efficiency 98% on 1.0 µm particles, increasing to 99.97% on 0.3 µm with an optional HEPA filter
Airflow Typically ranges from 170 to 1,699 m³/h (100 to 1,000 CFM)
Noise Level 70 to 76 dBA at a distance of 3 feet
  • Electrostatic Precipitators (ESP): These charged particles are then attracted to a group of oppositely charged collection plates into which they become trapped. ESPs can be very effective at collecting sub-micron and smoke hiding them in high-speed machining as well as exposure to fine mists.
Technical Data Details
Efficiency Often >99%, even for very fine particles
Particle Size Effective for particles as small as 0.01 microns
Power Consumption Low, as energy is only applied to the particles, not the entire gas stream
Maintenance Low due to having no moving parts or filter media
  • Media Filtration Collectors: The air goes into the filters and the filters hold the contaminants thus leaving the fresh air to go through. These also form an economical way to serve a number of applications but must have a maintained filter or be replaced regularly to ensure efficiency.
Technical Data Details
Efficiency Typically >99.9% for particles 0.5 microns or larger
Temperature Range Varies widely by media type, from 150°C to over 260°C
Inlet Concentration Can handle high dust loads, from 1 to 23 g/m³ (0.5 to 10 gr/ft³)
  • Hybrid Collectors: Hybrid collectors are a combination of the most effective features of several different technologies: a centrifugal or impingement stage plus high-efficiency media filters typically are found in the combination.
Technical Data Details
Efficiency Enhanced, as the system is optimized to capture a wider range of particle sizes
Cost-Effectiveness Can reduce operational costs by extending the lifespan of more expensive components
Maintenance Varies, but a pre-treatment stage can reduce maintenance on the final collection stage

Features of Coolant Mist Collector:

  • Improved Workers Safety and Health: Mist collectors eradicate dangerous air particles and volatile organic compounds breathing them in causes respiratory diseases, skin complications, and many other health conditions linked to metalworking fluid exposure.
  • Longer Equipment Life: Coolant Oil Mist Collectors can drastically lower maintenance requirements, increase the lifetime of your actual machinery, and prevent expensive downtimes due to the prevention of this contamination.
  • Better Air Quality and Visibility: This also avoids slippery floors and reduces the risk of any health hazards due to risk of fire outbreak by the residue of the oil, which is combustible.
  • Cost and Time Effectiveness: Coolant mist collector service providers in India systems lessen the usage and the waste of numbers of fluids through the recapture and draining of reclaimable coolants and oils thus decreasing discharge expendable sums.
  • Regulatory Adherence: Megamech Coolant Mist Collector form one of the core components of adherence to the strict occupational health and air quality regulations developed by bodies such as OSHA that stipulate the allowable exposures to air pollutant.

Applications of Coolant Mist Collector:

  • CNC Machining: Coolant Oil Mist Collector machines must have mist collectors so that it can be highly suitable to keep the work place in a good condition, prevent malfunctioning of the sensitive electronic controls, and safeguard the health of operators.
  • Grinding Operations: Multi-stage filtration or electrostatic precipitators of the mist collectors play a critical role in ensuring their capture and preventing their distribution in the facility and therefore resulting in a safer working environment.
  • Automotive Manufacturing: The automotive industry and everything from the manufacture of the engine components to the stamp duplication of body panels all depends on metalworking fluids. To ensure clean and safe environment both in assembly line and machining centers.
  • Metalworking and General Machining: In such environments, it is important to install Stand Alone Mist Collector to ensure the air is kept good, machine should not get damaged and safety regulation could be achieved.

AIR PEL TECHNIC is the outstanding coolant mist collector manufacturers in India, suppliers, service providers in India have ceased to be an option; it is a must have product. It is an effective instrument of manufacturers and suppliers who are committed to the provision of a safe, clean, and efficient place of work. These systems help block out airborne pollutants to not only safeguard your employees and machinery, but also generate operational productivity and cost reduction. Contact us for more details.

FAQs:

A mist collector's major function is to remove mist and smoke droplets from the filtered airstream. To accomplish this task a collector must coalesce small drops into larger ones, and then drain the collected coolant from the filters before they plug.

These tanks are designed to hold more water than the splash pad immediately requires, which ensures that the filtration system has a consistent supply of water